Feature | Value |
---|---|
ZCode-LC | |
Applications | Suitable for small and poorly aligned guard doors, sliding guards or protective covers |
Certified according to | ISO 13849-1; EN 62061, EN ISO 14119; EN 60204-1; EN 60947-5-3; UL508 |
Approvals | CE, TUV, UL |
Power supply | DC 24 V; +/- 10 %, max. 25 mA |
Number of outputs | 2 contactless safety outputs, 1 auxiliary output |
Contact rating (safe- & auxiliary outputs) | DC 24 V, max. 200 mA, short-circuit proof |
Minimum load current | DC 24 V; 1 mA |
Switching distance recommented, maximum | 5 mm, Sao 10 mm close / Sar 20 mm open |
Base material | Red PES (Polyester) |
Protection | IP67, IP69K (with M12-connector IP67) |
Ambient temperature | -25 °C to +80 °C |
PL; Cat.; SILCL (EN ISO 13849-1; EN 62061) | PL e; Cat.4 |
Vibration-, shock resistance | 10-55 Hz / 1 mm, 1 ms / 30 g |
Response times Switch on | 4 ms |
Response times Switch off | 2 ms |
Weight, dimensions | 200 g, 88 x 25 x 13 mm |
Order No. with 5 m cable, inclusive actuator | 940144 |
Order No. with M12 connector (Codeing A), 30 cm cable, inclusive actuator | 940145 - (extension cable M12 connector, 10 m, Order No. 941200) |
Accessories | |
Order No. spare actuator | 940159 |
Order No. M12 extension cable, 10 m lengths, female, 8-wire, open end cable | 941200 |
ZCode-LC 88x25x13 mm - safety switch
Downloads
All safety switches of the ZCode series operate in a non-contact manner via an encoded magnet system with a large switching distance and high tolerance against offset to the safety door. These can be actuated only with the actuator included in the scope of supply. The switching status is indicated by a LED.
The safety relays are completely dust- and waterproof (IP 67). The difference lies in different housing variants. For example, type ZCode-MC has a stainless steel housing for high temperature requirements or for high chemical resistance to environmental influences.