Address

Hermann ZANDER GmbH & Co. KG
Am Gut Wolf 15
52070 Aachen
GERMANY
Tel: +49 (0)241 910501-0
Fax: +49 (0)241 910501-38
E-mail: info@zander-aachen.de

Find us on Google Maps.

Contact form

Have you any questions about a product or an application? Fill out our contact form and we will answer shortly.

Contact form 

  

 

MINOS SLxD are safety emergency stop modules for monitoring emergency stop buttons, safety doors and light curtains, as well as contact reinforcement of safe outputs (e.g. safe PLC outputs) to machines and plants.

The modules are also certified for continuous operation in furnaces according to EN 50156-1 as well as EN 746-2. For use in the process industry these modules are certified according to IEC 61511-1.

SLxD:
Variant for max. requirements up to PL d / SILCL 2 (according to EN ISO 13849-1 bzw. IEC 62061). Test pulses at the safe output enable error detection during operation.

SL1D for dual-channel emergency stop circuit, safety door monitoring with short circuit monitoring

SL2D for light curtains, OSSD output or single-channel emergency stop

There are variants with manual start or auto-start.

These Module are available with screw terminals or tensile spring terminals.

Product Page: MINOS SLxD - Ultra Slim Safety Logic

Eigenschaft Wert
MINOS SLxD
Safety function Safety emergency stop, safety doors, light curtains, contact reinforcement, OSSD, continous operation of furnaces , stopp category 0
Certified according to EN ISO 13849-1; IEC 62061; IEC 61508;
EN 50156-1; EN 746-2IEC 61511-1; EN 60204-1
Approvals CE, TUV
Operating voltage UB: DC 24 V (+/- 10 %)
Power consumption at UB = 24V 2.4 W (module enabled via S11. No load)
Number dual-channel inputs 1
Number start input 1 (auto-start or manual start each variant)
Max. switching capacity O1 ut UB. max. 2.5 A (see derating in the operating instructions)
Maximum switching capacity auxiliary output C1 max. 100 mA
Max. switch-on delay 10 ms
Off-delay (if requested via the safety circuit) < 13 ms
Ambient temperatur -15 °C to 55 °C
(see derating in the operating instructions)
Protection IP20
Mounting 35 mm DIN-rail
PL; Kat.; SILCL (EN ISO 13849-1; EN 62061) PL d; SILCL 2
Dimension 6.2 x 93.1 x 102.5 mm
Manual Start: 50 g
Manueller Start:
MINOS SL1D, tensil spring terminal, manual start 472800
MINOS SL1D, screw terminal,manual start 472801
MINOS SL2D, tensil spring terminal, manual start 472804
MINOS SL2D, screw terminal, manual start 472805
Auto-Start:
MINOS SL1D, tensil spring terminal, auto-start 472802
MINOS SL1D, screw terminal, auto-start 472803
MINOS SL2D, tensil spring terminal, auto-start 472806
MINOS SL2D, screw terminal, auto-start 472807

Related Item / Accessories