Feature | Value |
---|---|
ZX21TP | |
Applications | Packaging machines, cutting facilities, bottling plants, gluing stations, plastic injection moulding machines, camshaft controller |
Supply voltage | DC 24 V +/- 15% |
Digital inputs | 20 x DC 18..30 V |
Digital outputs | 16 x semiconductor DC 10..30 V; 0.5 A |
Analog inputs | - |
Analog outputs | - |
INTERFACES: | |
Ethernet | 1; (10Base –T or 100Base-T), programming interface, expansion connector |
PROFINET | PROFINET IO Device interface |
Response time | < 20 ns |
Logic Capacity: Amount of configurable Logic Blocks (CLB´s*) | 896 CLBs; *each CLB includes more than 100 Gates, FlipFlops |
Process time digital inputs / outputs | < 9 μs at 250 mA per output |
Max. input frequency | 500 kHz |
Number of programmable timer | 50-200 |
Programming | EX_PRESS 5 for Windows Structured Text according to IEC61131-3 |
Width | 108 mm |
Order No. | 589052 |
Order No. software EX-PRESS 5 | 589092 |
ZX21TP high-speed-controller for PROFINET
Downloads
The new high speed controller ZX21TP also does not have any cycle time and thus, always ensures fastest possible - and even more important - constantly fast processes. How is this possible?
Often single high-speed requirements needs to be processed in integrated control systems.
E.g. recording of measurement data or pace critical activities like counting, sorting or printing of products. In this case ZX20 bus variants are the right choice. With integrated PROFINET IO-DEVICE (ZX21TP) single control systems can be integrated in higher systems.
This means:
- Direct, simple integration in higher control systems
- No additional hardware is necessary
- High-speed data transfer
The visualisation is possible with the help of ZANDER MVisio HMI via PROFINET