The controllers of the ZX09 series are also ideal as high-speed cam controllers. Absolute or incremental encoders can be used.

Absolute single- or multi-turn encoders are connected via an SSI interface (up to 20Mhz!); incremental encoders via TTL (up to 1MHz) or via standard 24V inputs of the ZX09 controller.

The implementation of the cam controller function in our programming tool EX_PRESS is very easy, by using a function block (SSI) or by direct logical queries in the program. Sample programs are available. And even complex sequences are processed in real time without cycle time.

Product Page: ZX09A - Cam Controller

Eigenschaft Wert
ZX09A
Applications Packaging machines, cutting facilities, bottling plants, gluing stations, plastic injection moulding machines, camshaft controller
Supply voltage DC 24 V +/- 15%
Digital inputs 10 x DC 18..30 V
Digital outputs 4 x DC 10..30 V; 0.5 A
Analog inputs 1; 0..10 V or 0..20 mA
Analog outputs -
INTERFACES:
RS485 / RS422 2
SSI 1 (2 - with reconfigured RS 485 interface);
10 Mbit/s, Multi-Turn, Single-Turn
Ethernet 1; (10Base-T or 100Base-T)
programming interface, expansion connector
Response time < 20 ns
Logic Capacity: Amount of configurable Logic Blocks (CLB´s*) 715 CLBs;
*each CLB includes more than 100 Gates, FlipFlops
Process time digital inputs / outputs < 3 μs
Time delay analog inputs < 10 µs
Max. input frequency 500 kHz
Number of programmable timer 2000
Programming EX_PRESS 5 for Windows Structured Text according to IEC61131-3
Width 108 mm
Order No. basic module 589201
Order No. software EX-PRESS 5 589092

Related Item / Accessories