Feature | Value |
---|---|
ZCode-LCE | |
Applications | Suitable for small and poorly aligned guard doors, sliding guards or protective covers |
Certified according to | ISO 13849-1; EN 62061, EN ISO 14119; EN 60204-1; EN 60947-5-3; UL508 |
Approvals | CE, TUV, UL |
Supply Voltage | DC 24 V; +/- 15 % |
Number of outputs | 2 contactless safety outputs, 1 auxiliary outputs |
Contact rating (safe- & auxiliary outputs) | DC 24 V; max. 200 mA; short-circuit proof |
Minimum load current | DC 24 V; 1 mA |
Switching distance recommented, maximum | 5 mm, 10 mm close / 22 mm open |
Base material | Stainless steel 316 |
Protection | IP67, IP69K (only Stainless Steel) |
Ambient temperature | -25 °C up to +105 °C |
PL; Kat.; SILCL (EN ISO 13849-1; EN /IEC 62061) | PL e; Kat.4; SILCL3* |
Vibration-, shock resistance | 10-55 Hz / 1 mm, 1 ms / 30 g |
Weight, dimensions | 200 g, 88 x 25 x 14 mm |
Order No. with M12 connector, 30 cm cable, inclusive actuator | 940147 - (extension cable M12 connector 10 m Order No. 941200) |
Accessories | |
Order No. spare actuator | 940149 |
Order No. M12 extension cable, 10 m lengths, female, 8-wire, open end cable | 941200 |
ZCode-LCE 80x25x14 mm - stainless steel safety switch
Downloads
All safety switches of the ZCode series operate in a Non-Contact manner via an encoded magnet system with a large switching distance and high tolerance against offset to the safety door. These can be actuated only with the actuator included in the scope of supply. The switching status is indicated by a LED.
The safety relays are completely dust- and waterproof (IP 69K). The difference lies in different housing variants. For example, type ZCode-LCE has a stainless steel housing for high temperature requirements or for high chemical resistance to environmental influences.